[Header]	
Customer Name	ILLUMINA, INC.
Product Type	15033972
Date Manufactured	11/06/2013
Lot	WO0000109373383
DesignStudio ID	29239
Target Plexity	52
	
[Probes]
Gene Name	Transcript ID	Assay ID	Left Exon	Right Exon	Species	Build ID	Chromosome	Start Position	End Position	ULSO Sequence	ULSO Genomic Hits	DLSO Sequence	DLSO Genomic Hits	Probe Strand	Designer	Design Score	SNP Masking	Labels
APAF1	NM_181861	6686842	3	4	Homo sapiens	hg19	chr12	99043428	99052978	TGCAGAAGCTGTTAGAGATCATTCCC	1	GGGAGTGCATTGGGTTTCAGTTGGGAAA	1	PLUS	ILLUMINA	1.897	false	FromReportXYZ;FromStudyXYZ
ATM	NM_000051	6688745	0	1	Homo sapiens	hg19	chr11	108093881	108098356	GGTTGATACTACTTTGACCTTCCGAGTG	1	TGTGTGTTCTGAAATTGTGAACCATGAG	1	PLUS	ILLUMINA	1.935	false	FromStudyXYZ
ATR	NM_001184	6798606	46	45	Homo sapiens	hg19	chr3	142172004	142168405	CACTGAATGAAACTGGAGAAGTTGTCA	1	CTTGACATTGAGCAGCGACTACAAG	1	MINUS	ILLUMINA	1.884	false	
BAI1	NM_001702	6834134	27	28	Homo sapiens	hg19	chr8	143624769	143625002	GAAGTCGCGGTATGCAGAACTGGACTTT	1	AGCGGCACCAAGACATGTTCCA	1	PLUS	ILLUMINA	1.408	false	
BCL2	NM_000633	6665875	1	0	Homo sapiens	hg19	chr18	60986441	60986151	TTGACAGAGGATCATGCTGTACT	3	CAGAGGAAGTAGACTGATATTAACAATACT	1	MINUS	ILLUMINA	1.37	false	
BCR	NM_004327	6674926	20	21	Homo sapiens	hg19	chr22	23656226	23656782	CTCACCTTCCTTTTCCTTCTGGACCA	9	CAATAAGATGTCCCTGCACAACC	16	PLUS	ILLUMINA	1.58	false	
BID	NM_197966	6680411	5	4	Homo sapiens	hg19	chr22	18220813	18218316	ACGCACCTACGTGAGGAGCTTA	3	GACAGTTCCAGAAGTGTGACTGGCTAA	1	MINUS	ILLUMINA	1.461	false	
BIRC5	NM_001012271	6629354	3	4	Homo sapiens	hg19	chr17	76212830	76219586	AAACTGGACAGAGAAAGAGCCAAGAAC	1	CAACAATAAGAAGAAAGAATTTGAGGAAAC	1	PLUS	ILLUMINA	1.717	false	
BRCA1	NM_007300	6730125	14	13	Homo sapiens	hg19	chr17	41228539	41226510	TCTACCAGTAAAAATAAAGAACCAGGAGTG	1	TCATCCCCTTCTAAATGCCCATCATTAG	1	MINUS	ILLUMINA	1.738	false	
BRCA2	NM_000059	6803185	13	14	Homo sapiens	hg19	chr13	32929393	32930594	TAACTTTCACAAAGTGTGAAGAAGAACC	1	TTTAATTACAAGTCTTCAGAATGCCAGAG	1	PLUS	ILLUMINA	1.818	false	
BTG2	NM_006763	6664924	0	1	Homo sapiens	hg19	chr1	203274834	203276260	AGGCTTAAGGTCTTCAGCGGGG	5	ACTACAAACACCACTGGTTTCCCGAA	1	PLUS	ILLUMINA	1.423	false	
CASP2	NM_001224	6695810	1	2	Homo sapiens	hg19	chr7	142988755	142989436	TCACCTTGGAAATGAGGGAGCTCAT	1	CAGCCAGAATGTGGAACTCCTCAACTT	1	PLUS	ILLUMINA	1.867	false	
CASP8	NM_033355	6847575	3	4	Homo sapiens	hg19	chr2	202136310	202137388	AGGAAATCTCCAAATGCAAACTGGATG	1	ACCTGCTGGATATTTTCATAGAGATGG	1	PLUS	ILLUMINA	1.994	false	
CASP9	NM_032996	6776537	8	7	Homo sapiens	hg19	chr1	15820417	15819505	CTCTGAAGACCTGCAGTCCCTCCT	2	TCGCTAATGCTGTTTCGGTGAAAGG	1	MINUS	ILLUMINA	1.599	false	
CCND1	NM_053056	6833728	2	3	Homo sapiens	hg19	chr11	69458729	69462799	GCGCAGACCTTCGTTGCCCTCTGT	2	CCAATCCGCCCTCCATGGTGGCA	7	PLUS	ILLUMINA	1.18	false	
CCNE1	NM_001238	6797467	5	6	Homo sapiens	hg19	chr19	30308412	30311644	AAAAATGCGAGCAATTCTTCTGGATTGG	1	GTCTATAAACTTCACAGGGAGACCTTT	1	PLUS	ILLUMINA	1.961	false	
CCNG1	NM_199246	6790545	2	3	Homo sapiens	hg19	chr5	162866492	162868127	TGAATTTACTGGACAGATTCCTGTCT	2	CTTGGGTGTGTTGGACTGAGCTGCTTTTA	1	PLUS	ILLUMINA	1.817	false	
CDK1	NM_001786	6732015	2	3	Homo sapiens	hg19	chr10	62544585	62545454	CTATTAAAGGAACTTCGTCATCCAAATAT	1	GATGTGCTTATGCAGGATTCCAGGTT	1	PLUS	ILLUMINA	1.803	false	
CDK4	NM_000075	6769529	1	0	Homo sapiens	hg19	chr12	58146000	58145476	CCCGATAACGGGCCGCCCCCACAGCA	1	GGCTACCTCTCGATATGAGCCAG	2	MINUS	ILLUMINA	1.188	false	
CDKN1A	NM_078467	6677447	2	3	Homo sapiens	hg19	chr6	36652287	36653560	TCTCAGGGTCGAAAACGGCGGCAGA	1	TCCAAACGCCGGCTGATCTTCT	1	PLUS	ILLUMINA	1.238	false	
CHEK1	NM_001114121	6747216	3	4	Homo sapiens	hg19	chr11	125499163	125499315	GATTCTTCCATCAACTCATGGCAGG	1	TTTATCTGCATGGTATTGGAATAACTCAC	1	PLUS	ILLUMINA	1.753	false	
CHEK2	NM_001005735	6675109	1	0	Homo sapiens	hg19	chr22	29137793	29130685	GCTGCGGAGAGTGTGCGGCTCCAGGT	1	TCTCGGGAGTCGGATGTTGAGG	5	MINUS	ILLUMINA	1.122	false	
CTNNB1	NM_001098210	6833435	0	1	Homo sapiens	hg19	chr3	41241134	41265540	CGCGGCGGGAGGAGCCTGTTCCCCTGA	1	GGTATTTGAAGTATACCATACAACTGTTT	1	PLUS	ILLUMINA	1.399	false	
E2F1	NM_005225	6647904	4	3	Homo sapiens	hg19	chr20	32266032	32265319	CTCTCCGAGGACACTGACAGCCA	5	TGGCCTACGTGACGTGTCAGGACCTT	1	MINUS	ILLUMINA	1.433	false	
E2F3	NM_001949	6696780	5	6	Homo sapiens	hg19	chr6	20488447	20490441	ACAATGGGAATATCCCTAAACCCGCT	2	TCAGGACATAGCGATTGCTCAGTTTC	3	PLUS	ILLUMINA	1.936	false	
ERBB2	NM_001005862	6740363	28	29	Homo sapiens	hg19	chr17	37883756	37883980	AGACTGATGGCTACGTTGCCCC	5	GCCAGATGTTCGGCCCCAGCCCCCTT	1	PLUS	ILLUMINA	1.121	false	
FASLG	NM_000639	6690598	2	3	Homo sapiens	hg19	chr1	172633502	172634789	GGAGCTGAGGAAAGTGGCCCATTTAA	2	CAAGTCCAACTCAAGGTCCATGCCTCT	1	PLUS	ILLUMINA	1.903	false	
GADD45A	NM_001924	6771929	2	3	Homo sapiens	hg19	chr1	68152242	68153384	CCCCGGACCTGCACTGCGTGCTGGTGA	1	CAATGGAAGGATCCTGCCTTAAGTCA	1	PLUS	ILLUMINA	1.598	false	
GML	NM_002066	6598615	0	1	Homo sapiens	hg19	chr8	143916254	143921865	CACGCACACTGCGGGGCTCCGA	2	CTCCTGCGTGAAGTGATGCTCCTCTTT	1	PLUS	ILLUMINA	1.304	false	
HDAC1	NM_004964	6610066	12	13	Homo sapiens	hg19	chr1	32798316	32798647	GAGAAAACCAAGGAGGAGAAGCCAGAA	2	GTCAAGGAGGAGGTCAAGTTGGCCTGAAT	2	PLUS	ILLUMINA	1.821	false	
HRAS	NM_176795	6603022	3	2	Homo sapiens	hg19	chr11	533800	533570	AACACCAAGTCTTTTGAGGACATCCAC	1	GGACTCGGATGACGTGCCCATG	1	MINUS	ILLUMINA	1.431	false	
JAK2	NM_004972	6734006	0	1	Homo sapiens	hg19	chr9	4985592	4985970	GCTCGAGGGCGCGCTCTGGTCG	2	AGAAGCAGGCAACAGGAACAAGATGT	1	PLUS	ILLUMINA	1.285	false	
KAT2B	NM_003884	6778646	5	6	Homo sapiens	hg19	chr3	20153247	20156408	AAAACGAACTCTAATCCTCACTCATTTCC	1	TGTCCATGCTAGAAGAAGAAGTATATAGTC	1	PLUS	ILLUMINA	1.649	false	
KITLG	NM_000899	6627175	1	0	Homo sapiens	hg19	chr12	88974073	88939607	GCAGCGCTGCCTTTCCTTATGAAGAA	1	CTCACTTGCATTTATCTTCAGCTGCTC	1	MINUS	ILLUMINA	1.943	false	
MDM2	NM_002392	6606061	0	1	Homo sapiens	hg19	chr12	69202239	69203026	CCAAGCGCGAAAACCCCGGATGGTGA	1	ATACCAACATGTCTGTACCTACTGATGG	1	PLUS	ILLUMINA	1.767	false	
MDM4	NM_002393	6764037	0	1	Homo sapiens	hg19	chr1	204485607	204494649	GCGGGGGAGCGACTCATGGAGCT	1	GACTGCAGTTTCTTCACTACCAAAATG	3	PLUS	ILLUMINA	1.477	false	
MLH1	NM_001167618	6810267	17	18	Homo sapiens	hg19	chr3	37090478	37092020	ATCTGAGGAGTCGACCCTCTCAG	2	CCAAACTCCTGGAAGTGGACTGT	4	PLUS	ILLUMINA	1.223	false	
NFKB1	NM_003998	6777413	5	6	Homo sapiens	hg19	chr4	103488264	103498066	ACTGCTGGACCCAAGGACATGGT	5	AACCTGGGTATACTTCATGTGACAAAG	1	PLUS	ILLUMINA	1.594	false	
NFKBIA	NM_020529	6810000	5	4	Homo sapiens	hg19	chr14	35871626	35871239	GAGTTCACGGAGTTCACAGAGGA	4	CCCTATGATGACTGTGTGTTTGGAG	2	MINUS	ILLUMINA	1.505	false	
PCNA	NM_002592	6850637	2	1	Homo sapiens	hg19	chr20	5100254	5099485	GCAACCTGGCCATGGGCGTGAA	9	ATGTCCAAAATACTAAAATGCGCCGGC	2	MINUS	ILLUMINA	1.416	false	
PPM1D	NM_003620	6844381	4	5	Homo sapiens	hg19	chr17	58734168	58740399	TGACTCCTTCCCCATGTTCTACACCA	1	CCAAGGGTGAATTCTAAGGACCA	6	PLUS	ILLUMINA	1.577	false	
PTEN	NM_000314	6846498	7	8	Homo sapiens	hg19	chr10	89720841	89725083	ACAAAGCCAACCGATACTTTTCTCCA	3	ACAAAAACAGTAGAGGAGCCGTCAA	2	PLUS	ILLUMINA	1.867	false	
RB1	NM_000321	6839911	25	26	Homo sapiens	hg19	chr13	49051510	49054160	TCCAAATTTCAGCAGAAACTGGCAG	7	TTCTACTCGAACACGAATGCAAAAGC	1	PLUS	ILLUMINA	1.867	false	
SERPINB5	NM_002639	6845383	2	3	Homo sapiens	hg19	chr18	61154287	61156605	TACGTAGACAAATCTCTGAATCTTTCTAC	1	GAGTTCATCAGCTCTACGAAGAGACC	1	PLUS	ILLUMINA	1.817	false	
SESN2	NM_031459	6695845	8	9	Homo sapiens	hg19	chr1	28605728	28607265	GAGGCACTTCCGCCACTCAGAGAA	2	CTGCTCCTGGAGGCGCGCATGCAA	2	PLUS	ILLUMINA	1.303	false	
SIRT1	NM_012238	6842392	7	8	Homo sapiens	hg19	chr10	69672760	69676056	AAAGGAGCAGATTAGTAGGCGGCTT	2	GTATCTGTTTTTGCCACCAAATCGTTAC	1	PLUS	ILLUMINA	1.852	false	
SRC	NM_198291	6774274	1	2	Homo sapiens	hg19	chr20	35993648	36011062	GCTATGAGAGACAGAGCCAGGATTTGA	1	CAGAGAGGGAAAGCCACTTGCCTA	156	PLUS	ILLUMINA	1.731	false	
TNF	NM_000594	6633875	1	2	Homo sapiens	hg19	chr6	31544322	31544571	CCTCTCTCTAATCAGCCCTCTGGC	3	ATCATCTTCTCGAACCCCGAGTGACAA	1	PLUS	ILLUMINA	1.696	false	
TNFRSF10B	NM_147187	6693526	3	2	Homo sapiens	hg19	chr8	22888302	22887208	TTCTGCTTGCGCTGCACCAGGTGTGATT	1	GTGGAGCTAAGTCCCTGCACCA	9	MINUS	ILLUMINA	1.319	false	
TP53	NM_001126114	6709182	7	6	Homo sapiens	hg19	chr17	7577524	7577127	ACCATCATCACACTGGAAGACTCCA	2	AATCTACTGGGACGGAACAGCTTTG	1	MINUS	ILLUMINA	1.771	false	
TP63	NM_003722	6727607	4	5	Homo sapiens	hg19	chr3	189582175	189584509	CCAACCATGAGCTGAGCCGTGAATTCAA	1	CCTCCTAGTCATTTGATTCGAGTAGAGG	1	PLUS	ILLUMINA	1.896	false	
TP73	NM_005427	6683610	8	9	Homo sapiens	hg19	chr1	3644754	3645916	TGGAGACGAGGACACGTACTACCTTCA	1	GCGAGGCCGGGAGAACTTTGAGAT	1	PLUS	ILLUMINA	1.664	false	
[Targets]
Gene Name	Transcript ID	Assay ID	Assay Position	Validated	Left Exon	Right Exon	Probe Strand	Target Sequence
APAF1	NM_181861	6686842	CENTER	false	3	4	PLUS	TTTCCCAACTGAAACCCAATGCACTCCCCCTGGGAAACAACCTTCTAAAAGGGAATGATCTCTAACAGCTTCTGCA
ATM	NM_000051	6688745	FIVE_PRIME	false	0	1	PLUS	CTCATGGTTCACAATTTCAGAACACACATCACTGTCACTGCACTCGGAAGGTCAAAGTAGTATCAACC
ATR	NM_001184	6798606	THREE_PRIME	false	46	45	MINUS	CTTGTAGTCGCTGCTCAATGTCAAGAACATGGGTCTTGGCCTTTTCATTGACAACTTCTCCAGTTTCATTCAGTG
BAI1	NM_001702	6834134	THREE_PRIME	false	27	28	PLUS	TGGAACATGTCTTGGTGCCGCTTCCGGGTGTGCATGATCTTCTCAAAGTCCAGTTCTGCATACCGCGACTTC
BCL2	NM_000633	6665875	FIVE_PRIME	false	1	0	MINUS	AGTATTGTTAATATCAGTCTACTTCCTCTGTGATGTTGTATTTTTTAAGTACAGCATGATCCTCTGTCAA
BCR	NM_004327	6674926	THREE_PRIME	false	20	21	PLUS	GGTTGTGCAGGGACATCTTATTGACTGCCTCCTTCTCTGCCACCCTTTTCAGGTGGTCCAGAAGGAAAAGGAAGGTGAG
BID	NM_197966	6680411	FIVE_PRIME	false	5	4	MINUS	TTAGCCAGTCACACTTCTGGAACTGTCCGTTCAGTCCATCCCATTTCTGGCTAAGCTCCTCACGTAGGTGCGT
BIRC5	NM_001012271	6629354	FIVE_PRIME	false	3	4	PLUS	GTTTCCTCAAATTCTTTCTTCTTATTGTTGGTTTCCTTTGCAATTTTGTTCTTGGCTCTTTCTCTGTCCAGTTT
BRCA1	NM_007300	6730125	CENTER	false	14	13	MINUS	CTAATGATGGGCATTTAGAAGGGGATGACCTTTCCACTCCTGGTTCTTTATTTTTACTGGTAGA
BRCA2	NM_000059	6803185	CENTER	false	13	14	PLUS	CTCTGGCATTCTGAAGACTTGTAATTAAATCTAAAGGTTCTTCTTCACACTTTGTGAAAGTTA
BTG2	NM_006763	6664924	FIVE_PRIME	false	0	1	PLUS	TTCGGGAAACCAGTGGTGTTTGTAGTGCTCTGTGAGTGCCTCCTGGAGCGCCCCGCTGAAGACCTTAAGCCT
CASP2	NM_001224	6695810	FIVE_PRIME	false	1	2	PLUS	AAGTTGAGGAGTTCCACATTCTGGCTGAAACTGCCCACTTTGGCCTGGATGAGCTCCCTCATTTCCAAGGTGA
CASP8	NM_033355	6847575	FIVE_PRIME	false	3	4	PLUS	CCATCTCTATGAAAATATCCAGCAGGTTCATGTCATCATCCAGTTTGCATTTGGAGATTTCCT
CASP9	NM_032996	6776537	THREE_PRIME	false	8	7	MINUS	CCTTTCACCGAAACAGCATTAGCGACCCTAAGCAGGAGGGACTGCAGGTCTTCAGAG
CCND1	NM_053056	6833728	CENTER	false	2	3	PLUS	TGCCACCATGGAGGGCGGATTGGAAATGAACTTCACATCTGTGGCACAGAGGGCAACGAAGGTCTGCGC
CCNE1	NM_001238	6797467	CENTER	false	5	6	PLUS	AAAGGTCTCCCTGTGAAGTTTATAGACTTCACACACCTCCATTAACCAATCCAGAAGAATTGCTCGCATTTTT
CCNG1	NM_199246	6790545	CENTER	false	2	3	PLUS	TAAAAGCAGCTCAGTCCAACACACCCAAGGTGCTTGGGCTGTACCTTCATTTTAGACAGGAATCTGTCCAGTAAATTCA
CDK1	NM_001786	6732015	FIVE_PRIME	false	2	3	PLUS	AACCTGGAATCCTGCATAAGCACATCCTGAAGACTGACTATATTTGGATGACGAAGTTCCTTTAATAG
CDK4	NM_000075	6769529	FIVE_PRIME	false	1	0	MINUS	CTGGCTCATATCGAGAGGTAGCCATTCTCAGATCAAGGGAGACCCTCACGCCAGCCCGGGGTGCTGTGGGGGCGGCCCGTTATCGGG
CDKN1A	NM_078467	6677447	FIVE_PRIME	false	2	3	PLUS	AGAAGATCAGCCGGCGTTTGGAGTGGTAGAAATCTGTCATGCTGGTCTGCCGCCGTTTTCGACCCTGAGA
CHEK1	NM_001114121	6747216	FIVE_PRIME	false	3	4	PLUS	GTGAGTTATTCCAATACCATGCAGATAAACCACCCCTGCCATGAGTTGATGGAAGAATC
CHEK2	NM_001005735	6675109	FIVE_PRIME	false	1	0	MINUS	CCTCAACATCCGACTCCCGAGACATCACGACCGCGTGAGCCCACCTGGAGCCGCACACTCTCCGCAGC
CTNNB1	NM_001098210	6833435	FIVE_PRIME	false	0	1	PLUS	AAACAGTTGTATGGTATACTTCAAATACCCTCAGGGGAACAGGCTCCTCCCGCCGCG
E2F1	NM_005225	6647904	CENTER	false	4	3	MINUS	AAGGTCCTGACACGTCACGTAGGCCAGGCGCTGGCTGTCAGTGTCCTCGGAGAG
E2F3	NM_001949	6696780	THREE_PRIME	false	5	6	PLUS	GAAACTGAGCAATCGCTATGTCCTGAGTTGGTTGAAGCCAAGTCTTTGGAAGCGGGTTTAGGGATATTCCCATTGT
ERBB2	NM_001005862	6740363	THREE_PRIME	false	28	29	PLUS	AAGGGGGCTGGGGCCGAACATCTGGCTGGTTCACATATTCAGGCTGGGGGCTGCAGGTCAGGGGGGCAACGTAGCCATCAGTCT
FASLG	NM_000639	6690598	THREE_PRIME	false	2	3	PLUS	AGAGGCATGGACCTTGAGTTGGACTTGCCTGTTAAATGGGCCACTTTCCTCAGCTCC
GADD45A	NM_001924	6771929	FIVE_PRIME	false	2	3	PLUS	TGACTTAAGGCAGGATCCTTCCATTGAGATGAATGTGGATTCGTCACCAGCACGCAGTGCAGGTCCGGGG
GML	NM_002066	6598615	FIVE_PRIME	false	0	1	PLUS	AAAGAGGAGCATCACTTCACGCAGGAGCCTGGACCTGTGCCCCTCGGAGCCCCGCAGTGTGCGTG
HDAC1	NM_004964	6610066	THREE_PRIME	false	12	13	PLUS	ATTCAGGCCAACTTGACCTCCTCCTTGACCCCTTTGGCTTCTGGCTTCTCCTCCTTGGTTTTCTC
HRAS	NM_176795	6603022	THREE_PRIME	false	3	2	MINUS	CATGGGCACGTCATCCGAGTCCTTCACCCGTTTGATCTGCTCCCTGTACTGGTGGATGTCCTCAAAAGACTTGGTGTT
JAK2	NM_004972	6734006	FIVE_PRIME	false	0	1	PLUS	ACATCTTGTTCCTGTTGCCTGCTTCTGAAACCGGCTACACAGATCGGGCGACCAGAGCGCGCCCTCGAGC
KAT2B	NM_003884	6778646	CENTER	false	5	6	PLUS	GACTATATACTTCTTCTTCTAGCATGGACAGAAATTTTGGGAAATGAGTGAGGATTAGAGTTCGTTTT
KITLG	NM_000899	6627175	FIVE_PRIME	false	1	0	MINUS	GAGCAGCTGAAGATAAATGCAAGTGAGAATCCAAGTTTGTGTCTTCTTCATAAGGAAAGGCAGCGCTGC
MDM2	NM_002392	6606061	FIVE_PRIME	false	0	1	PLUS	CCATCAGTAGGTACAGACATGTTGGTATTGCACATTTGCCTGCTCCTCACCATCCGGGGTTTTCGCGCTTGG
MDM4	NM_002393	6764037	FIVE_PRIME	false	0	1	PLUS	CATTTTGGTAGTGAAGAAACTGCAGTCTGTTGGTAAAACTTACGGCAGCTCCATGAGTCGCTCCCCCGC
MLH1	NM_001167618	6810267	THREE_PRIME	false	17	18	PLUS	ACAGTCCACTTCCAGGAGTTTGGAATGGAGCCAGGCACTTCACTCTGCTGGCCTGAGAGGGTCGACTCCTCAGAT
NFKB1	NM_003998	6777413	CENTER	false	5	6	PLUS	CTTTGTCACATGAAGTATACCCAGGTTTGCGAAGCCGACCACCATGTCCTTGGGTCCAGCAGT
NFKBIA	NM_020529	6810000	THREE_PRIME	false	5	4	MINUS	CTCCAAACACACAGTCATCATAGGGCAGCTCGTCCTCTGTGAACTCCGTGAACTC
PCNA	NM_002592	6850637	FIVE_PRIME	false	2	1	MINUS	GCCGGCGCATTTTAGTATTTTGGACATACTGGTGAGGTTCACGCCCATGGCCAGGTTGC
PPM1D	NM_003620	6844381	THREE_PRIME	false	4	5	PLUS	TGGTCCTTAGAATTCACCCTTGGCCATGGATCCTCCTCCAGTGACTTGACTGGTGGTGTAGAACATGGGGAAGGAGTCA
PTEN	NM_000314	6846498	THREE_PRIME	false	7	8	PLUS	TTGACGGCTCCTCTACTGTTTTTGTGAAGTACAGCTTCACCTTAAAATTTGGAGAAAAGTATCGGTTGGCTTTGT
RB1	NM_000321	6839911	THREE_PRIME	false	25	26	PLUS	GCTTTTGCATTCGTGTTCGAGTAGAAGTCATTTCTGCCAGTTTCTGCTGAAATTTGGA
SERPINB5	NM_002639	6845383	CENTER	false	2	3	PLUS	GGTCTCTTCGTAGAGCTGATGAACTCTGTAGAAAGATTCAGAGATTTGTCTACGTA
SESN2	NM_031459	6695845	THREE_PRIME	false	8	9	PLUS	TTGCATGCGCGCCTCCAGGAGCAGCAAGTTCACGTGGACCTTCTCTGAGTGGCGGAAGTGCCTC
SIRT1	NM_012238	6842392	THREE_PRIME	false	7	8	PLUS	GTAACGATTTGGTGGCAAAAACAGATACTGATTACCATCAAGCCGCCTACTAATCTGCTCCTTT
SRC	NM_198291	6774274	FIVE_PRIME	false	1	2	PLUS	TAGGCAAGTGGCTTTCCCTCTCTGGGCCTCAGCGTCCTCATCTGGTTTCAAATCCTGGCTCTGTCTCTCATAGC
TNF	NM_000594	6633875	FIVE_PRIME	false	1	2	PLUS	TTGTCACTCGGGGTTCGAGAAGATGATCTGACTGCCTGGGCCAGAGGGCTGATTAGAGAGAGG
TNFRSF10B	NM_147187	6693526	FIVE_PRIME	false	3	2	MINUS	TGGTGCAGGGACTTAGCTCCACTTCACCTGAATCACACCTGGTGCAGCGCAAGCAGAA
TP53	NM_001126114	6709182	THREE_PRIME	false	7	6	MINUS	CAAAGCTGTTCCGTCCCAGTAGATTACCACTGGAGTCTTCCAGTGTGATGATGGT
TP63	NM_003722	6727607	CENTER	false	4	5	PLUS	CCTCTACTCGAATCAAATGACTAGGAGGGGCAATCTGTCCCTCGTTGAATTCACGGCTCAGCTCATGGTTGG
TP73	NM_005427	6683610	THREE_PRIME	false	8	9	PLUS	ATCTCAAAGTTCTCCCGGCCTCGCACCTGAAGGTAGTACGTGTCCTCGTCTCCA
